| Switching Frequency |
XFR 2.8 kW: Nominal 31 kHz (62 kHz output ripple) XFR 1.2 kW: 6 V to 40 V models: nominal 78 kHz (156 kHz output ripple); 60 V to 600 V models: nominal 62.5 kHz (125 kHz output ripple). |
| Time Delay |
7 sec maximum from power on until output stable |
| Voltage Mode Transient Response Time |
< 3 ms for output voltage to recover within 0.5% of its rated voltage after a step change in load current of up
to 10% to 90% of rated output |
| Maximum Voltage Differential |
±600 Vdc from output to safety ground |
| Remote Start/Stop and Interlock |
2.5-15 V signal or TTL-compatible input, selectable logic |
| Remote Analog Programming |
Voltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances; 0-5 V, 0-10 V (default) voltage sources |
| Remote Analog Monitoring |
Voltage and current monitor outputs 0-5 V, 0-10 V (default) ranges for 0-100% of output |
| Remote Programming &
Monitoring Accuracy |
1% zero to full scale output for the default range |
| Maximum Remote Sense
Line Drop Compensation |
5 V / line (Line drop is subtracted from total voltage available at supply output.) |
| Front Panel Voltage and Current Control |
10-turn voltage and current potentiometers |
| Front Panel Voltage Control Resolution |
0.02% of maximum voltage |
| Main Output Connector |
XFR 2.8 kW: 7.5 - 100 V models: nickel-plated copper bus bars with bus bar cover and strain relief; 150V to 600 V models: 4-terminal, wire clamp connector with cover and strain relief; XFR 1.2 kW: 6 - 40 V models: nickel-plated copper bus bars with bus bar shield; 60 - 600 V models: 4-terminal wire clamp connector with strain relief |
| Approvals |
CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; UL Listed to UL3111-1; CSA certified to CSA C22.2 No 1010.1 Meets USA EMC standard: FCC, part 15B, Class A; Meets Canadian EMC standard: ICES-001, Class A. |